Transmission Type: | Flexible |
---|---|
Rhythm: | Flow Production Line |
Automatic Production Line: | Assembly |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical instruction: A: Temperature control segment: 40 segment The segment can be set in computer according to the actual requirement. B: Temperature-zone numbers: Single-zone and multi-segment C: Temperature control system: PC control system, SSR non-contact output D: Temperature accuracy: & plusmn; 2 C E: Warm-up time: 3min F: Temperature range: Room-temperature -360 C G: Heating supply: Infrared ray + Hot air convection H: Effective working table area: 270mm * 230mm (less than A4) I: Welding time: 3min & plusmn; 1min J Temperature curve: It can be set, adjusted and tested according to the actual requirement. K: Cooling system: Transverse flow equal cooling N: Rated voltage: AC single-phase, 220V; 50Hz O: Rated power: 4.0KW Mean power: 1.8kw P: Gross Weight: 82 kg Q: Dimension: Length * width * height: 820*460 *310mm |